CAT: BFP/VCAR
VAM04
P
T
IE/VAM04/001/2011 SHEET: 1/1
VAM 04 00 *
11
1/4 BSP
Ø 24
P
T
60.5
18.8
11
24
SINGLE-PHASE MOTOR START VALVE - IN-LINE MOUNTING
HYDRAULIC SYMBOL
HYDRAULIC FEATURES
VAM = Start valve
ORDERING CODE
Series
Size
04 = 1/4 BSP
00 = No variants
L = 0.8 ÷ 2.5 l/min
M = > 2.5 ÷ 8.0 l/min
H = > 8.0 ÷ 14 l/min
Max. working pressure
300 bar
Max. Flow 20 l/min
Min. working pressure 15 bar
Max operating frequency (with manual
operated)
1 Hz
Working Temperature -25°C ÷ 60°C
Hydraulic fluid DIN 51524 Mineral oils
Fluid viscosity 10 ÷ 500 mm
2
/s
Fluid temperature -25°C ÷ 75°C
Max. contamin. level class with filter ISO 4406:1999 - class 19/17/14
Weight 0.14 kg
Tightening torque 25 ÷ 30 Nm
Nominal flow
SOFT START VALVES
Variants
Valve used on power units to delay system pressurisation to allow a single-
phase motor to reach the required speed.
Fitted directly on the auxiliary pressure delivery line of unit 1 pumps or on the
delivery branch between pump and unidirectional valve.
The body is in steel and the tapered poppet in tempered and ground steel.
Page: 92
HOME INFO VALVES INDEX